Small angle X-ray scattering (SAXS) is a powerful and non­destructive method for analyzing nanostructure materials. The technique yields information such as particle sizes and size distributions from 1 to 100 nm, including shape and orientation distributions in liquid, powders and bulk samples. Applications range from life science and biotechnology (proteins, viruses, DNA complexes) to polymers, emulsions, liquid crystals, fibers and catalysts.
 
Home > Products > SAXS > S-Max3000
 

S-Max3000: Optional attachments

Horizontal Scanning Stage
Horizontal scanning capability used for precise two dimensional sample mapping. When coupled with the Automatic Sample Changer, a two dimensional array of 100 or more samples may be measured automatically.
 
Secondary Universal Sample Chamber with Automatic Sample Changer
Second sample chamber mounted downstream from main chamber to shorten sample to detector distance and enable measurement of higher q values without having to move the detector position
 
Linkam High Temperature Control Stage
The stage provides temperature control from -50 to 300°C with ± 0.1°C precision, using a combination of fluid coolant and an integral heater.
 
Capillary Cell Automatic Sample Changer
Measures up to 6 capillaries automatically
Designed for reproducible capillary positioning for accurate background solution subtraction
Temperature control by external water chiller/heater
 
Lock and Load Chamber for Introducing Image Plate for WAXS
Lock and Load feed through mounted on side of main SAXS chamber that allows Image plate to be introduced and removed from the system without breaking the vacuum. Center punch on image plates for simultaneous SAXS/WAXS measurement
 
Two Axis Goniometer
Provides sample rotation about two independent axes orthogonal to the beam direction.
 
Grazing Incidence/Reflectivity Module
The angles in and out of the plane of incidence are changed by the relative motion of three independent tangent drives. Sub-arc-second precision and accuracy for grazing incidence SAXS
 
Linkam Scientific TST350 Tensile Stage
Sample stage for multi-temperature measurements of samples under tensile stress.
Tensile Force range 0.01 N to 20 N. Temperature range -196 to 350°C
 
Linkam Scientific Shear Cell CSS450
Shear cell sample stage for multi-temperature measurements of samples under shear conditions. Ambient to 450°C
 
Linkam Scientific Differential Scanning Calorimeter DSC600
Integrated DSC unit with large temperature range -196 to 600°C for simultaneous measurement