Radioflex RF-200EGM2 specifications

Radioflex RF-250EGM2

Tube voltage 110 kV ~ 250 kV in steps of 2 kV
Tube current STD mode 5 mA (at 140 kV or more)
LOW mode ~ 4 mA (at 140 kV or more)
Duty cycle Intermittent continuous (1:1 Max. 6 min at 25°C)
X-ray tube Ceramic X-ray tube
Focal spot size (nominal) 2.0 mm x 2.0 mm
Inherent filter Aluminum 2 mm + Beryllium 1 mm
Dimensions Generator 320 (W) x 320 (D) x 632 (H) mm
Controller 360 (W) x 340 (D) x 208 (H) mm
Weight Generator 28.0 kg
Controller 17.2 kg
Power supply Single phase AC 190 V - 240 V 50/60Hz
Power consumption STD mode: 3.7 kVA
LOW mode: 2.8 kVA
Generator insulation SF6 insulation gas
Generator cooling Anode earth, forced air cooling by radiator